Home Products About Contact Services Dealers FAQ Get a quote
Controls and calibrators

Mindray lipid calibrator in the Philippines

A separate calibrator for the lipid panel, because those assays are not all covered by the general chemistry calibrator.

At a glance

Lipid Calib… CHEMISTRY CALIBRATION MINDRAY · FRAMAR
Also called Lipids calibrator, Lipid calibrator
Method Assayed lipid calibrator
Category Chemistry calibration
Discipline Controls and calibrators
Brand Mindray

What Lipid Calibrator does

The lipid assays need calibration material with assigned values appropriate to them, and the direct HDL and LDL methods in particular do not simply inherit calibration from a general chemistry calibrator. This material carries those values. It is used at installation, after a reagent lot change on any of the lipid assays, and when quality control indicates the lipid calibration has drifted. As with any calibrator the assigned values are lot-specific and are entered from the documentation supplied with the material rather than carried over, and the calibration is verified afterwards by running control material that is independent of it.

How Philippine laboratories run it

Any Philippine laboratory offering a lipid profile needs this alongside the general chemistry calibrator, and it is a frequent gap: laboratories order the multi-sera calibrator, assume it covers everything, and then find the lipid assays cannot be calibrated when a new reagent lot arrives. Because the lipid profile is standard in annual physical examination packages, that discovery tends to happen at the worst possible moment, in the middle of a corporate batch. Framar includes the lipid calibrator in the schedule wherever the lipid reagents are being supplied.

Analyzers it runs on

BS-600M BS-430 BS-360E BS-240Pro BS-230 BA-88A

Calibrator, controls and companion tests

Delivered with both control levels and the other control and calibrator materials for that bench, on the same schedule as Lipid Calibrator.

Chemistry Control Level 1 Chemistry Control Level 2 Multi-Sera Calibrator

Storage and handling

Refrigerated, and reconstituted or brought to room temperature exactly as the insert directs.

Buying Lipid Calibrator in the Philippines

Lipid Calibrator is supplied for the BS-600M, BS-430, BS-360E, BS-240Pro, BS-230 and BA-88A. We deliver it with Chemistry Control Level 1 and Chemistry Control Level 2, because a run held up waiting on a separate order costs the same shift a stock-out does. Delivery is scheduled against how fast your bench actually gets through it, which for a consumable is set by workload rather than by a calendar. How we plan controls and calibrators supply.

Questions about Lipid Calibrator

Does the multi-sera calibrator cover the lipid assays?

Not entirely, which is why this material exists. The direct HDL and LDL methods in particular need calibration material appropriate to them. Laboratories that stock only the general chemistry calibrator discover the gap when a lipid reagent lot changes and the assay cannot be calibrated, so it is worth confirming your coverage before that happens rather than after.

Order Lipid Calibrator

Tell us your monthly workload and we will quote a supply schedule for BS-600M. We reply within one business day.

Request a quotation

More controls and calibrators reagents

Multi-Sera Calibrator Chemistry Control Level 1 Chemistry Control Level 2 BC-3D Control BC-5D Control BC-6D Control Thyroid Control All 8 →

Other reagent groups

Clinical chemistry CLIA immunoassay Coagulation Hematology All reagents →

For in vitro diagnostic use by trained laboratory personnel. This page is product supply information for laboratories. It is not medical advice and does not describe how any condition is diagnosed or treated. Reference intervals, decision points and quality control policy are established by the reporting laboratory, and the package insert supplied with the product governs its use.

Call 💬WhatsApp Viber Quote