Clinical chemistry

Mindray LDL cholesterol reagent in the Philippines

The fraction lipid-lowering therapy is actually targeted at, measured directly rather than derived from the other three.

At a glance

LDL-C LIPID MINDRAY · FRAMAR
Analyte LDL cholesterol
Also called LDL, Low-density lipoprotein cholesterol, Bad cholesterol
Method Direct, homogeneous enzymatic
Sample type Serum, Plasma
Panel Lipid
Discipline Clinical chemistry
Brand Mindray

What LDL-C measures

Low-density lipoprotein carries cholesterol out to the tissues, and it is the fraction most directly implicated in atherosclerosis, which makes it the target of statin therapy and the number clinicians follow when treating. Many laboratories do not measure it at all, deriving it instead from total cholesterol, HDL and triglycerides using a long-established formula. That calculation is adequate in most fasting samples and unreliable in two common situations: when triglycerides are substantially raised, and when the patient has not fasted. A direct measurement removes that dependency, which matters most in exactly the patients whose lipids are hardest to interpret and who are most likely to be on treatment.

How Philippine laboratories run it

Most Philippine laboratories still report a calculated LDL as part of the standard lipid profile, so a direct LDL reagent is a considered addition rather than a default one. It earns its place in laboratories with a significant cardiology or endocrinology workload, where patients on lipid-lowering therapy are followed to a target and where raised triglycerides are common enough that calculated values are regularly unreportable. Laboratories weighing it up should look at how often their calculated LDL is currently suppressed for a high triglyceride, since that number is the case for the reagent.

Analyzers it runs on

BS-600M BS-430 BS-360E BS-240Pro BS-230 BA-88A

Compare the Mindray clinical chemistry range.

Calibrator, controls and companion tests

Delivered with its calibrator, both control levels and the rest of the lipid panel, on the same schedule as LDL-C.

Lipid Calibrator Chemistry Control Level 1 Chemistry Control Level 2 Total Cholesterol HDL-C Triglycerides

Storage and handling

Refrigerated and kept closed when off the analyzer.

Buying LDL-C in the Philippines

LDL-C is supplied for the BS-600M, BS-430, BS-360E, BS-240Pro, BS-230 and BA-88A. We deliver it with Lipid Calibrator and Chemistry Control Level 1, because a run held up waiting on a separate order costs the same shift a stock-out does. Delivery is scheduled against your monthly LDL-C count, so the bench is not rationing tests in the last week of the month. How we plan clinical chemistry supply.

Questions about LDL-C

Should we measure LDL directly or keep calculating it?

Calculation is adequate for most fasting samples with normal triglycerides, and it costs nothing extra. A direct measurement earns its place where triglycerides are often raised, where patients are not reliably fasting, or where you are following patients to an LDL target on treatment, because those are the cases in which the calculated value is either unreliable or cannot be reported at all.

Order LDL-C

Tell us your monthly LDL-C volume and we will quote a supply schedule for BS-600M. We reply within one business day.

Request a quotation

More clinical chemistry reagents

ALT (SGPT) AST (SGOT) ALP Total Protein Albumin Total Bilirubin Direct Bilirubin Urea (BUN) All 22 →

Other reagent groups

CLIA immunoassay Controls and calibrators Coagulation Hematology All reagents →

For in vitro diagnostic use by trained laboratory personnel. This page is product supply information for laboratories. It is not medical advice and does not describe how any condition is diagnosed or treated. Reference intervals, decision points and quality control policy are established by the reporting laboratory, and the package insert supplied with the product governs its use.