The fraction where a higher number is the better one, measured directly on the analyzer rather than calculated.

At a glance

HDL-C LIPID MINDRAY · FRAMAR
Analyte HDL cholesterol
Also called HDL, High-density lipoprotein cholesterol, Good cholesterol
Method Direct, accelerator selective detergent
Sample type Serum, Plasma
Panel Lipid
Discipline Clinical chemistry
Brand Mindray

What HDL-C measures

High-density lipoprotein carries cholesterol away from the tissues and back to the liver, and higher concentrations are associated with lower cardiovascular risk, which reverses the usual reading of a lipid result. It is measured directly on the analyzer using a reagent system that selectively makes the cholesterol in the HDL fraction available to the enzymatic reaction while leaving the other lipoproteins alone, which is why this reagent is chemically more involved than the total cholesterol reagent it accompanies. The measured HDL is also an input to the calculated LDL where a direct LDL is not run, and it is used in the cholesterol-to-HDL ratio that many risk assessments report.

How Philippine laboratories run it

HDL-C has been consistently among the highest-volume chemistry reagents in Framar’s delivery record, which reflects how routinely the full lipid profile is ordered in Philippine practice rather than any unusual clinical demand. It should be scheduled alongside total cholesterol and triglycerides in the same block, since a laboratory that runs out of HDL loses both the fraction itself and, where LDL is calculated, the LDL as well. Laboratories running the profile for corporate packages should expect the same batch pattern seen with the other lipids.

Analyzers it runs on

BS-600M BS-430 BS-360E BS-240Pro BS-230 BA-88A

Compare the Mindray clinical chemistry range.

Calibrator, controls and companion tests

Delivered with its calibrator, both control levels and the rest of the lipid panel, on the same schedule as HDL-C.

Lipid Calibrator Chemistry Control Level 1 Chemistry Control Level 2 Total Cholesterol Triglycerides LDL-C

Storage and handling

Refrigerated and kept closed when off the analyzer.

Buying HDL-C in the Philippines

HDL-C is supplied for the BS-600M, BS-430, BS-360E, BS-240Pro, BS-230 and BA-88A. We deliver it with Lipid Calibrator and Chemistry Control Level 1, because a run held up waiting on a separate order costs the same shift a stock-out does. Delivery is scheduled against your monthly HDL-C count, so the bench is not rationing tests in the last week of the month. How we plan clinical chemistry supply.

Questions about HDL-C

Is HDL cholesterol measured or calculated?

On the Mindray BS series it is measured directly, using a reagent system that makes only the HDL fraction available to the enzymatic reaction. That is a meaningful difference from LDL, which many laboratories still calculate, because a directly measured value stays valid when triglycerides are raised whereas a calculated one does not.

What is the cholesterol to HDL ratio, and do we need a reagent for it?

No separate reagent is needed. The ratio is calculated by dividing the measured total cholesterol by the measured HDL, so the two assays already on the bench produce it. Many Philippine reports include it alongside the individual values because it expresses in one number how much of the total sits in the protective fraction.

Order HDL-C

Tell us your monthly HDL-C volume and we will quote a supply schedule for BS-600M. We reply within one business day.

Request a quotation

More clinical chemistry reagents

ALT (SGPT) AST (SGOT) ALP Total Protein Albumin Total Bilirubin Direct Bilirubin Urea (BUN) All 22 →

Other reagent groups

CLIA immunoassay Controls and calibrators Coagulation Hematology All reagents →

For in vitro diagnostic use by trained laboratory personnel. This page is product supply information for laboratories. It is not medical advice and does not describe how any condition is diagnosed or treated. Reference intervals, decision points and quality control policy are established by the reporting laboratory, and the package insert supplied with the product governs its use.